Manufacturer: Jotun Paints
Description
Conseal Touch-up is a single pack, quick drying, high build acrylic primer / finish. It is a versatile and easy to use multipurpose coating for either direct to steel and other metals, or as a touch up coat in atmospheric environments. It has a matt finish and can be tinted to a large colour range.
Suitable for application onto hand prepared surfaces (Minimum St 2 -ISO 8501-1:2007).
- Matt finish
- High build
- Fast drying
- Can be used direct to metal.
- Can be applied at sub zero surface temperatures.
Application Method | Spray, Brush or Roller |
Surfaces | Refineries, Power Plants, Bridges & Buildings |
VOC Level | 470g / Litre |
Coverage | 4.1m² / Litre |
Touch Dry | 30 Minutes @ 10°C / 15 Minutes @ 40°C |
Over-Coating | 2 Hours 30 Minutes @ 10°C / 1 Hour 30 MInutes @ 40°C |
Maintenance Cycle | 2 Years |
Thinning & Cleaning | Jotun Thinner No.7 |
Number of Coats | 2 |
Additional Information
Typical Use: Conseal Touch-up is a versatile and easy to use primer/finish for multipurpose use either direct to steel and other metals or for use as a touch up coat. It is a single component, high build coating which can be tinted to a large colour range.
Protective: Recommended for refineries, power plants, bridges and buildings. Suitable for a wide range of industrial structures.
Surface Preparation: All surfaces should be clean, dry and free from contamination. The surface should be assessed and treated in accordance with ISO 8504.
Bare steel: Cleanliness: Power tool cleaning to min. St 2, mill scale free (ISO 8501-1:1988). Improved surface treatment (blast cleaning to Sa 21⁄2) will improve the performance.
Coated surfaces: Clean, dry and undamaged compatible primer. Contact us for more information. For maintenance UHPWJ to WJ2 (NACE No.5/SSPC-SP 12) or Power tool cleaning to min. St 2 for rusted areas.
Other surfaces: For aluminium and galvanized surface; degreasing, light abrading or sand sweeping. The coating may be used on other substrates.
Please contact us for more information.
Typical Paint System: Conseal Touch-up 1 x 120 μm (DFT) or Barrier 77 1 x 40 μm (DFT), Conseal Touch-up 1 x 75 μm (DFT)
Other systems may be specified, depending on area of use.
Application:
Spray - If airless spray is used the paint must be diluted 5-10 % with Jotun Thinner No. 7.
Brush - Use a suitable brush. Care must be taken to achieve the specified dry film thickness.
Roller - May be used, but is not recommended for first coat on bare metal. Care must be taken to achieve the specified dry film thickness.
Application Data: Mixing ratio (volume) Single pack. Thinner/Cleaner Jotun Thinner No. 7
Guiding Data Airless Spray |
Pressure at nozzle | 15 MPa (150 kp/cm², 2100 PSI) |
Nozzle Tip | 0.45 - 0.66mm (0.018 - 0.026") |
Spray Angle | 40 - 65° |
Filter | Check to ensure that filters are clean |
Continue Shopping